UNC Unidentified Gas (UIG) Workgroup 17 March 2020 Assessment Headlines Xoserve presented information on the number of sites in End User Category 7 and 8, which represent 4.5% of all distribution-connected Annual Quantities. More than 40% did not have a proper Winter Annual Ratio Band so were contributing to UIG. Xoserve proposed requiring these sites to move to Class 2, or redefining Class 1 to include them. Attendees were unconvinced but preferred the latter. UNC691 CDSP to Convert Class 2, 3 or 4 Meter Points to Class 1 when G1.6.15 Criteria are Met will need an extension as further amendments have been identified as necessary. The UNC672 Target, Measure and Reporting Product ...